Evaluation of a robotic compounding system for the preparation of non-hazardous ready to administer sterile products in a tertiary care hospital

Pdf

PDF Icon

European Statement

Production and Compounding

Author(s)

Clara Estaún-Martínez, Catalina Perelló-Alomar, Ángela Bueno, Naiara Tellería, Olga Delgado-Sánchez

Why was it done?

Automated compounding emerges as an alternative for manual compounding, making possible the centralisation of standardised compounded medications in hospital pharmacy aseptic services at a larger scale. This provides sterile, high-quality, safe, traceable ready to administer products to clinical units. Additionally, it could free up nursing time for patient care instead of performing pharmaceutical work.

What was done?

We evaluated productivity, dose accuracy and environmental monitoring of KIRO Fill®, a robotic compounding system (RCS). We also assessed the microbiological results of the sterility tests performed.

How was it done?

We implemented a RCS equipped with ISO 5 aseptic environment, horizontal airflow with HEPA filters and continuous monitoring of: air flow operation, non-viable particle counts (limits for ISO Class 5 are 0.5μm and larger size: not more than 3.520 particles/m3, and 5μm and larger size: not more than 20 particles/m3) and temperature (not more than 25°C). Two automated units work in parallel handling transfer syringes to withdraw solutions from source containers (SC) and fill final containers (syringes or infusion bags) via Luer Lock connections. This technology allows barcode/data matrix verification of source and final containers used and RFID for in-process tracking. An integrated scale is responsible for gravimetric control of the compounded preparations within an acceptable ± 5% error range. Gri-Fill® filling system was used for the preparation of SC.
Drug verification was assured through drug workflow management system and datamatrix verification in RCS.
We performed sterility test of all batches and physicochemical stability studies were developed when not available in the literature.

What has been achieved?

Between January 2022 and September 2022, we have prepared with RCS 2.813 syringes of norepinephrine (base) 0,2 mg/ml in normal saline for critical care unit syringe pumps and 395 morphine hydrochloride 1mg/ml normal saline 250 ml infusion bags for patient-controlled analgesia (PCA) administered in the surgical area.
The average dose accuracy errors for syringes and infusion bags were 0.23% and –0.09%, respectively. Environmental monitoring results and temperature controls met our standards at all times.
Results from sterility tests demonstrated the absence of microbial growth in all tested preparations

What next?

Overall satisfactory results when compounding sterile preparations using KIRO Fill and the positive feedback received from nurses in clinical units, have led us to incorporate new batches, such as morphine syringes for critical care unit syringe pumps, to the production with the RCS. Stability studies are currently being performed for this purpose.

×

EAHP Forum

All the EAHP team is working on providing a Forum that can help connect all the members in Conversations and Groups to talk about important matters for the European Hospital Pharmacist.

The Forum will be accessible for all the EAHP members, you don’t have to create a new account to browse and participate.

Conversations and groups

The Conversations will be moderated by our team to provide documents and relevant topics for the community.

The Groups will connect all members that share a category. Members who work on the same assocation, on the same hospital, that have the same role, etc.

Stay tuned for the realase of the forum. Soon on EAHP.